Architectural acoustics 1 (8 mins, ~7 MB) - podcast episode cover

Architectural acoustics 1 (8 mins, ~7 MB)

Nov 17, 20088 min
--:--
--:--
Download Metacast podcast app
Listen to this episode in Metacast mobile app
Don't just listen to podcasts. Learn from them with transcripts, summaries, and chapters for every episode. Skim, search, and bookmark insights. Learn more

Episode description

Sound rays obey Snell’s law of reflection. When they strike a surface the fraction of sound energy absorbed is known as the absorption coefficient, which varies with frequency. The time for the reverberant sound in a room to drop by 60dB is known as the reverberation time R. This can be calculated from the formula R = 0.16 V/A where V is the volume in cubic metres and a is the total absorption in metric Sabin i.e. the sum of the surface areas times their absorption coefficients. If R is large the sound in the room will lack clarity but the sound level will be large. If R is small the sound will be clear but the sound level will be low. Typically R will be 1s for a theatre and 1.5-2s for a concert hall.
For the best experience, listen in Metacast app for iOS or Android