StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor

Nov 21, 20221 min
--:--
--:--
Download Metacast podcast app
Listen to this episode in Metacast mobile app
Don't just listen to podcasts. Learn from them with transcripts, summaries, and chapters for every episode. Skim, search, and bookmark insights. Learn more

Episode description

StarDICE I: sensor calibration bench and absolute photometric calibration of a Sony IMX411 sensor by Marc Betoule et al. on Monday 21 November The Hubble diagram of type-Ia supernovae (SNe-Ia) provides cosmological constraints on the nature of dark energy with an accuracy limited by the flux calibration of currently available spectrophotometric standards. The StarDICE experiment aims at establishing a 5-stage metrology chain from NIST photodiodes to stars, with a targeted accuracy of \SI{1}{mmag} in $griz$ colors. We present the first two stages, resulting in the calibration transfer from NIST photodiodes to a demonstration \SI{150}{Mpixel} CMOS sensor (Sony IMX411ALR as implemented in the QHY411M camera by QHYCCD). As a side-product, we provide full characterization of this camera. A fully automated spectrophotometric bench is built to perform the calibration transfer. The sensor readout electronics is studied using thousands of flat-field images from which we derive stability, high resolution photon transfer curves and estimates of the individual pixel gain. The sensor quantum efficiency is then measured relative to a NIST-calibrated photodiode. Flat-field scans at 16 different wavelengths are used to build maps of the sensor response. We demonstrate statistical uncertainty on quantum efficiency below \SI{0.001}{e^-/\gamma} between \SI{387}{nm} and \SI{950}{nm}. Systematic uncertainties in the bench optics are controlled at the level of \SI{1e-3}{e^-/\gamma}. Uncertainty in the overall normalization of the QE curve is 1\%. Regarding the camera we demonstrate stability in steady state conditions at the level of \SI{32.5}{ppm}. Homogeneity in the response is below \SI{1}{\percent} RMS across the entire sensor area. Quantum efficiency stays above \SI{50}{\percent} in most of the visible range, peaking well above \SI{80}{\percent} between \SI{440}{nm} and \SI{570}{nm}. Differential non-linearities at the level of \SI{1}{\percent} are detected. A simple 2-parameter model is proposed to mitigate the effect. arXiv: http://arxiv.org/abs/http://arxiv.org/abs/2211.04913v2
For the best experience, listen in Metacast app for iOS or Android